RUC Series VSD Pump

RUC – Uruz VSD Booster Pump

RUC is a self-priming, variable-speed booster for residential and commercial clean-water pressure boosting. Its permanent magnet motor adjusts speed as demand changes. Fill the pump body before first start and check the selected model’s curve and suction limits. For a higher-flow installation with a flooded inlet, compare the BWD series.

Discuss distribution or bulk orders for RUC.

  • Motor: Permanent magnet synchronous motor.
  • Pressure control: Variable-speed operation for constant-pressure water supply.
  • Local display: View operating and target pressure, with buttons for adjustment.
  • Built-in protection: Soft start/stop, water-shortage and input-voltage protection.
  • Construction: IP55 protection and Class F insulation.
Products Categories
Get A Free Quote
Contact Form

RUC VSD Booster Pump Description

Residential water supply

Choose the residential RUC model by its performance curve, required flow and pressure. Water source, inlet conditions, elevation and pipework all affect selection.

Control and protection

The controller displays operating and target pressure. Functions include soft start/stop, water-shortage protection, overcurrent protection, input overvoltage and undervoltage protection, and a pipeline leakage warning.

Choose your control version

Version Control functions
Lite Local variable-speed control. No Wi-Fi, Bluetooth or Pump Link.
Pro Local control plus Pump Link for a compatible pump pair.
Max Local control plus Wi-Fi and Bluetooth for remote control and monitoring.
Ultra Local control, Wi-Fi, Bluetooth and Pump Link.

Before first operation

Fill the pump body with clean water before starting. Follow the selected model’s installation and operating limits. Commercial RUC configurations have separate specifications.

APPROVALS & TESTING

Confidence for Your Water Supply Project

Recognised approvals and test documentation help you specify the right RUC pump for your market.

WRAS

WRAS Approved

For specified RUC models in water-supply installations.

Models & document details

Approval 260704712. Models: RUC-370, 550, 750, 900, 1100, 1500 and 2200. Valid to 31 July 2031. Subject to the WRAS listing and installation requirements. Certificate to be supplied with supporting letter.

ACS

Sanitary Conformity

Documentation for drinking-water contact applications.

Models & document details

Eurofins ACS 26 ACC NY 922. Covers RUC-370, 550, 750, 900, 1100, 1500 and 2200. Issued 22 October 2026; expires 3 September 2031.

AS/NZS 4020

Drinking-Water Contact Tested

Test evidence to support project specification.

Models & document details

Report 2026ZJP01739, issued 26 October 2026. AS/NZS 4020:2018 + Amd 1:2022. RUC-370 tested; listed RUC models covered under the report’s stated construction and material conditions. Test report, not WaterMark certification.

TÜV SÜD

Safety Conformity Assessed

Independent assessment for listed electrical versions.

Models & document details

Attestation M8A 136600 0002 Rev. 00, dated 26 March 2026; report 871282601006-00. RUC-370/550/750/900/1100, 220–240 V~, 50/60 Hz. Does not replace the EU Declaration of Conformity.

Request Your Product Documentation

Send your contact details and the pump model you need. We share the files after approving your request.

Approval and test report covers

Cover of WRAS approval 260704712 for RAFSUN pumps
WRAS approval for listed RUC models.
ACS certificate cover for listed RAFSUN RUC booster pumps
ACS certificate for seven listed RUC models.
Cover of the TÜV SÜD attestation for listed 220–240 V booster pumps
TÜV SÜD attestation for the listed 220–240 V models.
Cover of AS/NZS 4020 test report for the RUC-370 sample
AS/NZS 4020 test report for a RUC-370 sample.

Residential RUC Technical Data

RUC performance specifications

Model Power Flow rate Head
RUC-370 370 W Maximum: 4 m³/h / 17.61 US gpm
Rated: 2 m³/h / 8.81 US gpm
Maximum: 37 m / 121.4 ft
Rated: 20 m / 65.6 ft
RUC-550 550 W Maximum: 5 m³/h / 22.01 US gpm
Rated: 3 m³/h / 13.21 US gpm
Maximum: 50 m / 164.0 ft
Rated: 24 m / 78.7 ft
RUC-750 750 W Maximum: 5.5 m³/h / 24.22 US gpm
Rated: 3 m³/h / 13.21 US gpm
Maximum: 55 m / 180.4 ft
Rated: 30 m / 98.4 ft
RUC-900 900 W Maximum: 6 m³/h / 26.42 US gpm
Rated: 3 m³/h / 13.21 US gpm
Maximum: 63 m / 206.7 ft
Rated: 38 m / 124.7 ft
RUC-1100 1100 W Maximum: 10.5 m³/h / 46.23 US gpm
Rated: 6 m³/h / 26.42 US gpm
Maximum: 60 m / 196.9 ft
Rated: 31 m / 101.7 ft

Selection note: Rated flow and head form the rated duty point. Maximum flow and maximum head are separate limits; select against the performance curve.

Electrical Supply

Parameter Specification
Power supply Single-phase AC (1~), 50/60 Hz, for all five models.
Input voltage — Option 1 165–260 V AC; available for RUC-370, RUC-550, RUC-750, RUC-900 and RUC-1100.
Input voltage — Option 2 95–145 V AC; available for RUC-370, RUC-550, RUC-750, RUC-900 and RUC-1100.
Dual-voltage input — Option 3 Automatic selection between 95–145 V AC and 165–260 V AC is listed for RUC-550, RUC-750 and RUC-900 only. This option is not listed as available for RUC-370 or RUC-1100.
Electrical configuration Specify the required voltage option when ordering. Options 1 and 2 are separate supply configurations; automatic dual-voltage selection applies only to the Option 3 version. Connect the installed pump according to its nameplate.

Installation Data

Parameter Specification
Inlet × outlet RUC-370, RUC-550, RUC-750 and RUC-900: 1 in × 1 in. RUC-1100: 1¼ in × 1¼ in. These are nominal connection sizes; confirm the required thread standard and mating pipework when ordering.
Maximum suction lift 8 m / 26.2 ft for all five models. Actual suction performance depends on the installation and operating conditions.
Maximum speed 5,200 r/min for all five models.
Pump protection / insulation IP55 / Class F for all five models. Keep the pump ventilated and protect it from immersion.
Priming and installation Fill the pump body with clean water before starting; use watertight pipe connections and follow the installation manual.

Operating Conditions — Ultra

Parameter Specification
Pumped liquid — Ultra manual Clean water; pH 6.5–8.5.
Particle limits Solid-particle volume fraction below 0.1%; particle size below 0.2 mm / approximately 0.0079 in.
Water temperature Above 3°C and below 75°C / above 37.4°F and below 167°F, as specified in the operating manual.
Ambient temperature 0–40°C / 32–104°F.
Relative humidity Maximum 85% RH.

Operating conditions: Water quality, temperature and humidity limits above follow the Ultra manual. Follow the manual supplied with your version.

Units: US-unit equivalents are rounded. US gpm means US gallons per minute.

Commercial RUC Models

RUC-1500
Power: 1,500 W
Max. flow: 18.5 m³/h
Max. head: 70 m
RUC-2200
Power: 2,200 W
Max. flow: 19.5 m³/h
Max. head: 73 m

Both models: 165–260 V AC, single phase, 50/60 Hz. Select using the pump curve at your required flow and head. Confirm the control version and number of linked pumps before ordering.

Request the manual or pump curve for your RUC model

Send your contact details and the pump model you need. We share the files after approving your request.

RUC Booster Pump Applications

  • Homes and villas: Household water supply and pipeline pressure boosting.
  • Small apartment buildings: Clean-water supply sized for simultaneous demand.
  • Gardens and greenhouses: Irrigation matched to the required flow and pressure.
  • Storage tanks and shallow wells: Supply from storage tanks, rainwater collection tanks or shallow wells, within the selected model’s suction limits.

Confirm water quality and inlet conditions. Municipal connections must follow local installation requirements.

Need help selecting a model? Send your required flow and pressure, water source, inlet conditions, supply voltage, phase and frequency, installation layout and preferred control version.

Request RUC model selection and a quotation

Installation questions

Can the pump draw water from a tank or shallow well?

Check the selected model’s suction capability and the actual water level. A catalogue maximum suction lift is a limit, not a guaranteed operating depth. Inlet pipe losses, air leaks and site conditions must be checked, and the pump must be filled before first use.

Can I connect two or more pumps?

Standard supported Pro and Ultra configurations link two compatible pumps. The newer RUC-1500/2200 catalogue describes a separate Pro+ configuration for 2–6 pumps. Confirm the supplied controller, firmware and availability before ordering a multi-pump system. Select the assembly from its combined performance curve and specify the required connection kit.

Related Products

Related News

A VFD booster pump uses a variable frequency drive to adjust motor speed in response to pressure feedback. It adds […]

A variable speed booster pump adjusts its motor speed to regulate water pressure as demand changes. A pressure sensor and […]

Scroll to Top

Talk to RAFSUN About Your Pump Requirements

Rafsun Solar Water Pump-0

Get A Free Quote Now !

VSD Contact Form

See our Privacy Policy for how we handle your information.

Contact Rafsun to get the service for free

RAFSUN BWD, HMS, RUC and REB variable-speed booster pump range

Get A Free Quote Now !

VSD Contact Form

See our Privacy Policy for how we handle your information.