Skip image slider
RAFSUN HMS Series Variable Speed Booster Pump
RAFSUN HMS Series Variable Speed Booster Pump

HMS – Benta VSD Booster Pump

HMS variable-speed booster pumps combine a permanent magnet motor and pressure control for homes and small apartment buildings.

  • Motor and control: Permanent magnet synchronous motor with variable-speed constant-pressure control.
  • Model range: HMS-750 and HMS-1500.
  • Impeller: AISI 304 stainless steel.
  • Protection: IP55 pump protection, Class F insulation and a potted controller circuit board.
  • Control choices: Lite, Pro, Max and Ultra versions.
Products Categories
Get A Free Quote
Contact Form

HMS VSD Booster Pump Description

Choose the Required Flow and Pressure

The HMS range uses a permanent magnet synchronous motor and variable-frequency control to adjust pump speed as water demand changes. Choose between HMS-750 and HMS-1500 using the flow needed at the required pressure, rather than motor power alone.

Select the Control Version

Version Control options
Lite Variable-speed constant-pressure control without Wi-Fi, Bluetooth or Pump Link.
Pro Pump Link for a compatible two-pump arrangement.
Max Wi-Fi and Bluetooth for remote control and monitoring.
Ultra Wi-Fi, Bluetooth and Pump Link for compatible single- or twin-pump configurations.

Check the Installation

HMS pumps use an AISI 304 impeller and a controller circuit board sealed with potting compound. The range has IP55 pump protection and Class F insulation. Check the inlet and outlet sizes, electrical supply and available suction conditions for the selected model.

Request a Model Recommendation

Send RAFSUN the water source, simultaneous flow demand, target pressure, elevation, pipe losses and preferred control version. These details help match the pump and its configuration to your installation.

Documentation You Can Specify With Confidence

AS/NZS 4020

Drinking-water contact test documentation for listed HMS models.

View scope & report details

Report 2026ZJP01739, issued 26 October 2026, to AS/NZS 4020:2018 + Amd 1:2022. Lists HMS-750, HMS-1500 and HMS-2200. RUC-370 was the test specimen; coverage is subject to the report’s construction and material conditions. This is a test report, not WaterMark certification.

TÜV SÜD

Independent safety conformity assessment for listed 220–240 V models.

View models & document details

Attestation M8A 136600 0002 Rev. 00, dated 26 March 2026. Models: HMS-750 and HMS-1500; 220–240 V~, 50/60 Hz. Test report 871282601006-00. The attestation does not replace the manufacturer’s EU Declaration of Conformity.

Request documentation for your HMS pump

Send your contact details and the pump model you need. We share the files after approving your request.

HMS Technical Data and Operating Conditions

Performance by Model

Parameter HMS-750 HMS-1500
Power 750 W 1,500 W
Maximum flow 6.8 m³/h (29.9 US gpm) 10 m³/h (44.0 US gpm)
Maximum head 52 m (170.6 ft) 70 m (229.7 ft)
Rated flow 3.5 m³/h (15.4 US gpm) 5 m³/h (22.0 US gpm)
Rated head 30 m (98.4 ft) 40 m (131.2 ft)
Maximum speed 4,800 rpm 4,800 rpm

Selection note: Maximum flow and maximum head are separate limits. Select the duty point from the performance curve.

Electrical and Installation Data

Parameter HMS-750 HMS-1500
Input option 1 165–260 VAC, single-phase 165–260 VAC, single-phase
Input option 2 95–145 VAC, single-phase Not available
Frequency 50/60 Hz 50/60 Hz
Inlet × outlet (nominal) 1 in × 1 in 1¼ in × 1 in
Maximum suction lift 8 m (26.2 ft) 8 m (26.2 ft)
Maximum water temperature 75°C (167°F) 75°C (167°F)
Pump protection rating IP55 IP55
Insulation class F F

Electrical selection: These are separate voltage versions, not automatic dual-voltage operation. Match the ordered version to the pump nameplate.

Connections: Sizes are nominal. Confirm BSP/NPT thread type and compatible fittings when ordering.

Ultra-Version Operating Conditions

Condition Specification
Pumped liquid Clean water
Liquid temperature 3°C < T < 75°C (37.4°F < T < 167°F)
Ambient temperature 0–40°C (32–104°F)
pH 6.5–8.5
Solid-particle content Less than 0.1% by volume
Particle size Less than 0.2 mm (approximately 0.0079 in)
Relative humidity Maximum 85% RH

Operating limits: These operating limits apply to the Ultra version. Water must remain below 75°C (167°F). Follow the manual supplied with your version.

Installation: HMS is non-self-priming. Fill the pump body with clean water before starting. Maximum suction lift is 8 m. Confirm the water source and inlet pipework for your site. IP55 does not permit immersion.

Units: US-unit equivalents are rounded. US gpm means US gallons per minute.

HMS Booster Pump Applications

  • Homes and small apartment buildings: Water supply and pressure boosting matched to simultaneous demand.
  • Gardens and greenhouses: Irrigation systems selected for the required flow and pressure.
  • Storage and rainwater tanks: Clean-water supply from tanks within the installation limits.
  • Municipal water supply: Pressure boosting where local requirements permit the connection.

Related Products

Related News

A VFD booster pump uses a variable frequency drive to adjust motor speed in response to pressure feedback. It adds […]

A variable speed booster pump adjusts its motor speed to regulate water pressure as demand changes. A pressure sensor and […]

Scroll to Top

Talk to RAFSUN About Your Pump Requirements

Rafsun Solar Water Pump-0

Get A Free Quote Now !

VSD Contact Form

See our Privacy Policy for how we handle your information.

Contact Rafsun to get the service for free

RAFSUN BWD, HMS, RUC and REB variable-speed booster pump range

Get A Free Quote Now !

VSD Contact Form

See our Privacy Policy for how we handle your information.