BWD VSD Booster Pump Description
Choose the Required Flow and Pressure
The BWD range combines a permanent magnet synchronous motor with variable-frequency control to adjust pump speed as water demand changes. Choose BWD-900, BWD-1200 or BWD-2200 by the required duty point and performance curve.
Select the Control Version
| Version |
Control options |
| Lite |
Basic variable-speed constant-pressure control; no Wi-Fi, Bluetooth or Pump Link. |
| Pro |
Pump Link for a compatible two-pump arrangement. |
| Max |
Wi-Fi and Bluetooth for remote control and monitoring. |
| Ultra |
Wi-Fi, Bluetooth and Pump Link for compatible single- or twin-pump configurations. |
Check Construction and Installation
The BWD catalogue specifies an AISI 304 impeller, IP55 pump protection and Class F insulation. Potting compound seals the controller circuit board.
Request a Model Recommendation
Share the water source, required flow and pressure, elevation, pipe losses, electrical supply and preferred control version. RAFSUN can then recommend a configuration and provide a quotation.
Documentation You Can Specify With Confidence
AS/NZS 4020
Drinking-water contact test documentation for listed BWD models.
View scope & report details
Report 2026ZJP01739, issued 26 October 2026, to AS/NZS 4020:2018 + Amd 1:2022. Lists BWD-900, BWD-1200, BWD-1500 and BWD-2200. RUC-370 was the test specimen; coverage is subject to the report’s construction and material conditions. This is a test report, not WaterMark certification.
TÜV SÜD
Independent safety conformity assessment for listed 220–240 V models.
View models & document details
Attestation M8A 136600 0002 Rev. 00, dated 26 March 2026. Models: BWD-900, BWD-1200 and BWD-2200; 220–240 V~, 50/60 Hz. Test report 871282601006-00. The attestation does not replace the manufacturer’s EU Declaration of Conformity.
Request documentation for your BWD pump
Send your contact details and the pump model you need. We share the files after approving your request.
BWD Technical Data
Performance by Model
| Parameter |
BWD-900 |
BWD-1200 |
BWD-2200 |
| Power |
900 W |
1,200 W |
2,200 W |
| Maximum flow |
8.5 m³/h (37.4 US gpm) |
10 m³/h (44.0 US gpm) |
20 m³/h (88.1 US gpm) |
| Maximum head |
53 m (173.9 ft) |
70 m (229.7 ft) |
60 m (196.9 ft) |
| Rated flow |
4 m³/h (17.6 US gpm) |
5 m³/h (22.0 US gpm) |
12 m³/h (52.8 US gpm) |
| Rated head |
30 m (98.4 ft) |
40 m (131.2 ft) |
40 m (131.2 ft) |
| Maximum speed |
4,800 rpm |
4,600 rpm |
4,500 rpm |
Selection note: Maximum flow and maximum head are separate limits. Select the duty point from the performance curve.
Electrical and Installation Data
| Parameter |
BWD-900 |
BWD-1200 |
BWD-2200 |
| Input option 1 |
165–260 VAC, single-phase |
165–260 VAC, single-phase |
165–260 VAC, single-phase |
| Input option 2 |
95–145 VAC, single-phase |
95–145 VAC, single-phase |
Not available |
| Frequency |
50/60 Hz |
50/60 Hz |
50/60 Hz |
| Inlet × outlet (nominal) |
1¼ in × 1¼ in |
1¼ in × 1¼ in |
2 in × 2 in |
| Maximum suction lift* |
8 m (26.2 ft) |
8 m (26.2 ft) |
8 m (26.2 ft) |
| Maximum water temperature |
75°C (167°F) |
75°C (167°F) |
75°C (167°F) |
| Pump protection rating |
IP55 |
IP55 |
IP55 |
| Insulation class |
F |
F |
F |
Electrical selection: These are separate voltage versions, not automatic dual-voltage operation. Match the ordered version to the pump nameplate.
Connections: Sizes are nominal. Confirm BSP/NPT thread type and compatible fittings when ordering.
Ultra-Version Operating Conditions
| Condition |
Specification |
| Pumped liquid |
Clean water |
| Liquid temperature |
3°C < T < 75°C (37.4°F < T < 167°F) |
| Ambient temperature |
0–40°C (32–104°F) |
| pH |
6.5–8.5 |
| Solid-particle content |
Less than 0.1% by volume |
| Particle size |
Less than 0.2 mm (approximately 0.0079 in) |
| Relative humidity |
Maximum 85% RH |
Operating limits: These operating limits apply to the Ultra version. Water must remain below 75°C (167°F). Follow the manual supplied with your version.
Installation: BWD models are non-self-priming. Fill the pump body with clean water before startup. Maximum suction lift is 8 m. Confirm the inlet arrangement and site conditions with RAFSUN before selection. IP55 does not permit immersion.
Units: US-unit equivalents are rounded. US gpm means US gallons per minute.
BWD Booster Pump Applications
- Homes and apartments: Water supply and pipeline pressure boosting, sized for simultaneous demand.
- Gardens and greenhouses: Irrigation systems matched to the required flow and pressure.
- Commercial water systems: Select the model against the project duty point.
- Water sources: Storage tanks, rainwater collection tanks or municipal supplies where locally permitted.