RUC is a self-priming, variable-speed booster for residential and commercial clean-water pressure boosting. Its permanent magnet motor adjusts speed as demand changes. Fill the pump body before first start and check the selected model’s curve and suction limits. For a higher-flow installation with a flooded inlet, compare the BWD series.
Choose the residential RUC model by its performance curve, required flow and pressure. Water source, inlet conditions, elevation and pipework all affect selection.
Control and protection
The controller displays operating and target pressure. Functions include soft start/stop, water-shortage protection, overcurrent protection, input overvoltage and undervoltage protection, and a pipeline leakage warning.
Choose your control version
Version
Control functions
Lite
Local variable-speed control. No Wi-Fi, Bluetooth or Pump Link.
Pro
Local control plus Pump Link for a compatible pump pair.
Max
Local control plus Wi-Fi and Bluetooth for remote control and monitoring.
Ultra
Local control, Wi-Fi, Bluetooth and Pump Link.
Before first operation
Fill the pump body with clean water before starting. Follow the selected model’s installation and operating limits. Commercial RUC configurations have separate specifications.
APPROVALS & TESTING
Confidence for Your Water Supply Project
Recognised approvals and test documentation help you specify the right RUC pump for your market.
WRAS
WRAS Approved
For specified RUC models in water-supply installations.
Models & document details
Approval 260704712. Models: RUC-370, 550, 750, 900, 1100, 1500 and 2200. Valid to 31 July 2031. Subject to the WRAS listing and installation requirements. Certificate to be supplied with supporting letter.
ACS
Sanitary Conformity
Documentation for drinking-water contact applications.
Models & document details
Eurofins ACS 26 ACC NY 922. Covers RUC-370, 550, 750, 900, 1100, 1500 and 2200. Issued 22 October 2026; expires 3 September 2031.
AS/NZS 4020
Drinking-Water Contact Tested
Test evidence to support project specification.
Models & document details
Report 2026ZJP01739, issued 26 October 2026. AS/NZS 4020:2018 + Amd 1:2022. RUC-370 tested; listed RUC models covered under the report’s stated construction and material conditions. Test report, not WaterMark certification.
TÜV SÜD
Safety Conformity Assessed
Independent assessment for listed electrical versions.
Models & document details
Attestation M8A 136600 0002 Rev. 00, dated 26 March 2026; report 871282601006-00. RUC-370/550/750/900/1100, 220–240 V~, 50/60 Hz. Does not replace the EU Declaration of Conformity.
Send your contact details and the pump model you need. We share the files after approving your request.
Approval and test report covers
WRAS approval for listed RUC models.ACS certificate for seven listed RUC models.TÜV SÜD attestation for the listed 220–240 V models.AS/NZS 4020 test report for a RUC-370 sample.
Residential RUC Technical Data
RUC performance specifications
Model
Power
Flow rate
Head
RUC-370
370 W
Maximum: 4 m³/h / 17.61 US gpm
Rated: 2 m³/h / 8.81 US gpm
Maximum: 37 m / 121.4 ft
Rated: 20 m / 65.6 ft
RUC-550
550 W
Maximum: 5 m³/h / 22.01 US gpm
Rated: 3 m³/h / 13.21 US gpm
Maximum: 50 m / 164.0 ft
Rated: 24 m / 78.7 ft
RUC-750
750 W
Maximum: 5.5 m³/h / 24.22 US gpm
Rated: 3 m³/h / 13.21 US gpm
Maximum: 55 m / 180.4 ft
Rated: 30 m / 98.4 ft
RUC-900
900 W
Maximum: 6 m³/h / 26.42 US gpm
Rated: 3 m³/h / 13.21 US gpm
Maximum: 63 m / 206.7 ft
Rated: 38 m / 124.7 ft
RUC-1100
1100 W
Maximum: 10.5 m³/h / 46.23 US gpm
Rated: 6 m³/h / 26.42 US gpm
Maximum: 60 m / 196.9 ft
Rated: 31 m / 101.7 ft
Selection note: Rated flow and head form the rated duty point. Maximum flow and maximum head are separate limits; select against the performance curve.
Electrical Supply
Parameter
Specification
Power supply
Single-phase AC (1~), 50/60 Hz, for all five models.
Input voltage — Option 1
165–260 V AC; available for RUC-370, RUC-550, RUC-750, RUC-900 and RUC-1100.
Input voltage — Option 2
95–145 V AC; available for RUC-370, RUC-550, RUC-750, RUC-900 and RUC-1100.
Dual-voltage input — Option 3
Automatic selection between 95–145 V AC and 165–260 V AC is listed for RUC-550, RUC-750 and RUC-900 only. This option is not listed as available for RUC-370 or RUC-1100.
Electrical configuration
Specify the required voltage option when ordering. Options 1 and 2 are separate supply configurations; automatic dual-voltage selection applies only to the Option 3 version. Connect the installed pump according to its nameplate.
Installation Data
Parameter
Specification
Inlet × outlet
RUC-370, RUC-550, RUC-750 and RUC-900: 1 in × 1 in. RUC-1100: 1¼ in × 1¼ in. These are nominal connection sizes; confirm the required thread standard and mating pipework when ordering.
Maximum suction lift
8 m / 26.2 ft for all five models. Actual suction performance depends on the installation and operating conditions.
Maximum speed
5,200 r/min for all five models.
Pump protection / insulation
IP55 / Class F for all five models. Keep the pump ventilated and protect it from immersion.
Priming and installation
Fill the pump body with clean water before starting; use watertight pipe connections and follow the installation manual.
Operating Conditions — Ultra
Parameter
Specification
Pumped liquid — Ultra manual
Clean water; pH 6.5–8.5.
Particle limits
Solid-particle volume fraction below 0.1%; particle size below 0.2 mm / approximately 0.0079 in.
Water temperature
Above 3°C and below 75°C / above 37.4°F and below 167°F, as specified in the operating manual.
Ambient temperature
0–40°C / 32–104°F.
Relative humidity
Maximum 85% RH.
Operating conditions: Water quality, temperature and humidity limits above follow the Ultra manual. Follow the manual supplied with your version.
Units: US-unit equivalents are rounded. US gpm means US gallons per minute.
Commercial RUC Models
RUC-1500 Power: 1,500 W Max. flow: 18.5 m³/h Max. head: 70 m
RUC-2200 Power: 2,200 W Max. flow: 19.5 m³/h Max. head: 73 m
Both models: 165–260 V AC, single phase, 50/60 Hz. Select using the pump curve at your required flow and head. Confirm the control version and number of linked pumps before ordering.
Send your contact details and the pump model you need. We share the files after approving your request.
RUC Booster Pump Applications
Homes and villas: Household water supply and pipeline pressure boosting.
Small apartment buildings: Clean-water supply sized for simultaneous demand.
Gardens and greenhouses: Irrigation matched to the required flow and pressure.
Storage tanks and shallow wells: Supply from storage tanks, rainwater collection tanks or shallow wells, within the selected model’s suction limits.
Confirm water quality and inlet conditions. Municipal connections must follow local installation requirements.
Need help selecting a model? Send your required flow and pressure, water source, inlet conditions, supply voltage, phase and frequency, installation layout and preferred control version.
Can the pump draw water from a tank or shallow well?
Check the selected model’s suction capability and the actual water level. A catalogue maximum suction lift is a limit, not a guaranteed operating depth. Inlet pipe losses, air leaks and site conditions must be checked, and the pump must be filled before first use.
Can I connect two or more pumps?
Standard supported Pro and Ultra configurations link two compatible pumps. The newer RUC-1500/2200 catalogue describes a separate Pro+ configuration for 2–6 pumps. Confirm the supplied controller, firmware and availability before ordering a multi-pump system. Select the assembly from its combined performance curve and specify the required connection kit.