Skip image slider
6 Inch ACDC Solar Submersible Pump With Stainless Steel Impeller
6 Inch ACDC Solar Submersible Pump With Stainless Steel Impeller

6 Inch AC/DC Solar Submersible Pump With Stainless Steel Impeller

6RCS-A/D 6-inch hybrid solar submersible pumps with stainless steel impellers. Match PV operation and an approved AC supply option to your well, water demand and installation.

  • Stainless steel impellers in a 6-inch submersible pump family.
  • Permanent-magnet motor with a matched hybrid solar inverter.
  • PV and AC supply options for a correctly configured system.
  • Selected catalogue models: 1,100-4,000 W.
  • Model-dependent limits up to 65 m³/h (286.2 US gpm) or 101 m (331.4 ft); maximum flow and maximum head are separate limits.
Products Categories
Get A Free Quote
Contact Form

6RCS-A/D Hybrid Solar Submersible Pump Overview

The RAFSUN 6RCS-A/D combines a submersible pump with stainless steel impellers and a compatible hybrid solar inverter. PV power supports daytime pumping, while a correctly matched grid or generator supply can support water delivery when solar power is insufficient.

14Catalogue models
1,100–4,000 WPump power range
AC/DCSpecified supply options

Select by the required operating point

Choose a model for flow at total dynamic head, including the pumping water level, delivery elevation, required pressure and pipe losses. The rated flow and rated head below form the catalogue duty point; maximum flow and maximum head must not be used together as a duty point.

Match both electrical supplies

The AC input, DC input and PV Vmp columns describe different quantities. Choose the pump and inverter as a matched system, and confirm supply phase, frequency, voltage and PV string design with the quotation. AC/PV operating behaviour and any simultaneous-input mode depend on the supplied inverter configuration.

Build around the water demand

Use daily water volume, local sunshine and available storage to plan solar operation. Specify the AC backup requirement for periods when solar energy is unavailable. Compare related sizes in the hybrid solar submersible range, or review DC solar well pumps for a DC system.

6RCS-A/D Model and Electrical Comparison

Selected catalogue models. Rated duty is shown as flow at head. US gpm and feet are rounded conversions. Electrical figures below are the model catalogue ranges; confirm the supplied inverter nameplate and wiring instructions before installation.

Models up to 2.2 kW

Model Power (W) Rated duty / m³/h at m Max. flow / m³/h / US gpm Max. head / m / ft AC range (V) DC range (V) PV Vmp (V) Outlet (in)
6RCS33-19-150-1100-A/D 1,100 17 at 13 / 74.8 US gpm at 42.7 ft 33 / 145.3 US gpm 19 / 62.3 ft 90-300 90-430 150-430 3
6RCS37-22-200-1500-A/D 1,500 17 at 16 / 74.8 US gpm at 52.5 ft 37 / 162.9 US gpm 22 / 72.2 ft 90-300 90-430 200-430 3
6RCS37-40-300-2200-A/D 2,200 17 at 25 / 74.8 US gpm at 82.0 ft 37 / 162.9 US gpm 40 / 131.2 ft 90-300 90-430 300-430 3
6RCS30-55-300-2200-A/D 2,200 17 at 29 / 74.8 US gpm at 95.1 ft 33 / 145.3 US gpm 55 / 180.4 ft 90-300 90-430 300-430 3
6RCS40-17-200-1500-A/D 1,500 20 at 16 / 88.1 US gpm at 52.5 ft 40 / 176.1 US gpm 24 / 78.7 ft 90-300 90-430 200-430 3
6RCS37-43-300-2200-A/D 2,200 20 at 23 / 88.1 US gpm at 75.5 ft 37 / 162.9 US gpm 43 / 141.1 ft 90-300 90-430 300-430 3
6RCS35-50-300-2200-A/D 2,200 20 at 27 / 88.1 US gpm at 88.6 ft 35 / 154.1 US gpm 50 / 164.0 ft 90-300 90-430 300-430 3

Models above 2.2 kW

Model Power (W) Rated duty / m³/h at m Max. flow / m³/h / US gpm Max. head / m / ft AC range (V) DC range (V) PV Vmp (V) Outlet (in)
6RCS30-72-500-3000-A/D 3,000 14 at 43 / 61.6 US gpm at 141.1 ft 30 / 132.1 US gpm 72 / 236.2 ft 330-420 200-750 500-750 3
6RCS37-63-500-3000-A/D 3,000 17 at 42 / 74.8 US gpm at 137.8 ft 37 / 162.9 US gpm 63 / 206.7 ft 330-420 200-750 500-750 3
6RCS46-51-500-3000-A/D 3,000 20 at 35 / 88.1 US gpm at 114.8 ft 46 / 202.5 US gpm 51 / 167.3 ft 330-420 200-750 500-750 3
6RCS65-24-500-3000-A/D 3,000 30 at 19 / 132.1 US gpm at 62.3 ft 65 / 286.2 US gpm 24 / 78.7 ft 330-420 200-750 500-750 3
6RCS30-101-500-4000-A/D 4,000 14 at 61 / 61.6 US gpm at 200.1 ft 30 / 132.1 US gpm 101 / 331.4 ft 330-420 200-750 500-750 3
6RCS46-68-500-4000-A/D 4,000 20 at 49 / 88.1 US gpm at 160.8 ft 46 / 202.5 US gpm 68 / 223.1 ft 330-420 200-750 500-750 3
6RCS65-47-500-4000-A/D 4,000 30 at 36 / 132.1 US gpm at 118.1 ft 65 / 286.2 US gpm 47 / 154.2 ft 330-420 200-750 500-750 3

Maximum flow and maximum head are not simultaneous. Confirm the required point on the selected model curve. Outlet dimensions do not identify BSP or NPT threads; specify the required connection standard.

PV array sizing

The catalogue recommends PV rated power of at least 1.3 times pump power as initial guidance. Final array design must account for site conditions, module voltage and current, cable losses and the matched inverter. Operating DC voltage and PV Vmp are not the array open-circuit voltage (Voc) limit. Check cold-weather string Voc against the actual inverter maximum before connection.

Installation and controls

  • Use the selected inverter manual for AC/PV terminals, grounding, motor connections and protective devices.
  • Keep the submersible pump underwater during operation and use suitable suspension equipment; never lift it by its electrical cable.
  • Confirm water-level sensors, pressure-control accessories and remote-control options in the system specification.
  • Use qualified personnel to commission the system. Confirm the permitted supply arrangement before enabling any simultaneous AC/PV mode.

Confirm the duty point against the supplied performance curve before ordering.

6RCS-A/D Hybrid Solar Pump Applications

  • Agricultural irrigation: match the operating point to field pipework and irrigation demand.
  • Livestock and farm supply: fill storage tanks from a suitable well.
  • Rural water transfer: combine daytime solar pumping with an appropriately specified AC supply option.
  • Scheduled water delivery: size pump capacity and storage for the daily requirement and available power.

Confirm water quality, allowable solids, bore clearance and installation depth for the selected model.

Request Your 6RCS-A/D System Selection

Send your country, bore diameter, pumping water level, delivery height, pipe length, required flow or daily volume, and quantity. Include the AC supply voltage/phase and PV module Vmp, Voc and wattage. We will help specify a pump, inverter and supply arrangement for your site.

Related Products

Related News

Scroll to Top

Talk to RAFSUN About Your Pump Requirements

Rafsun Solar Water Pump-0

Get A Free Quote Now !

VSD Contact Form

Contact Rafsun to get the service for free

RAFSUN flagship inverter booster pumps product lineup for factory direct sales, featuring BWD Cullinan (900–2200W), BWE Bentayga (750–1500W), RUC Urus (370–1100W), and REB Huracan (370–750W). These high-efficiency RAFSUN Inverter Booster Pumps deliver constant water pressure, energy savings, and reliable performance for residential, commercial, and multi-story building applications.

Get A Free Quote Now !

VSD Contact Form