Skip image slider
3or4 Inch ACDC Solar Submersible Pump With Plastic Impeller
3or4 Inch ACDC Solar Submersible Pump With Plastic Impeller

4 Inch AC/DC Solar Submersible Pump With Plastic Impeller

4RCP-A/D 4-inch hybrid solar submersible pumps with plastic impellers. Match PV operation and an approved AC supply option to your well, water demand and installation.

  • Plastic impellers in a 4-inch submersible pump family.
  • Permanent-magnet motor with a matched hybrid solar inverter.
  • PV and AC supply options for a correctly configured system.
  • Selected catalogue models: 750-4,000 W.
  • Model-dependent limits up to 41 m³/h (180.5 US gpm) or 303 m (994.1 ft); maximum flow and maximum head are separate limits.
Products Categories
Get A Free Quote
Contact Form

4RCP-A/D Hybrid Solar Submersible Pump Overview

The RAFSUN 4RCP-A/D combines a submersible pump with plastic impellers and a compatible hybrid solar inverter. PV power supports daytime pumping, while a correctly matched grid or generator supply can support water delivery when solar power is insufficient.

61Catalogue models
750–4,000 WPump power range
AC/DCSpecified supply options

Select by the required operating point

Choose a model for flow at total dynamic head, including the pumping water level, delivery elevation, required pressure and pipe losses. The rated flow and rated head below form the catalogue duty point; maximum flow and maximum head must not be used together as a duty point.

Match both electrical supplies

The AC input, DC input and PV Vmp columns describe different quantities. Choose the pump and inverter as a matched system, and confirm supply phase, frequency, voltage and PV string design with the quotation. AC/PV operating behaviour and any simultaneous-input mode depend on the supplied inverter configuration.

Build around the water demand

Use daily water volume, local sunshine and available storage to plan solar operation. Specify the AC backup requirement for periods when solar energy is unavailable. Compare related sizes in the hybrid solar submersible range, or review DC solar well pumps for a DC system.

Technical Data (Part 1)

Selected catalogue models. Rated duty is shown as flow at head. US gpm and feet are rounded conversions. Electrical figures below are the model catalogue ranges; confirm the supplied inverter nameplate and wiring instructions before installation.

Models up to 2.2 kW

Model Power (W) Rated duty / m³/h at m Max. flow / m³/h / US gpm Max. head / m / ft AC range (V) DC range (V) PV Vmp (V) Outlet (in)
4RCP4.6-75-110-750-A/D 750 2 at 55 / 8.8 US gpm at 180.4 ft 4.6 / 20.3 US gpm 75 / 246.1 ft 90-300 90-430 110-430 1.25
4RCP4.6-85-110-900-A/D 900 2 at 65 / 8.8 US gpm at 213.3 ft 4.6 / 20.3 US gpm 85 / 278.9 ft 90-300 90-430 110-430 1.25
4RCP4.6-95-150-1100-A/D 1,100 2 at 70 / 8.8 US gpm at 229.7 ft 4.6 / 20.3 US gpm 95 / 311.7 ft 90-300 90-430 150-430 1.25
4RCP4.6-110-150-1300-A/D 1,300 2 at 85 / 8.8 US gpm at 278.9 ft 4.6 / 20.3 US gpm 110 / 360.9 ft 90-300 90-430 150-430 1.25
4RCP4.6-130-200-1500-A/D 1,500 2 at 95 / 8.8 US gpm at 311.7 ft 4.6 / 20.3 US gpm 130 / 426.5 ft 90-300 90-430 200-430 1.25
4RCP4.6-150-200-1500-A/D 1,500 2 at 105 / 8.8 US gpm at 344.5 ft 4.6 / 20.3 US gpm 150 / 492.1 ft 90-300 90-430 200-430 1.25
4RCP4.6-175-300-2200-A/D 2,200 2 at 140 / 8.8 US gpm at 459.3 ft 4.6 / 20.3 US gpm 175 / 574.1 ft 90-300 90-430 300-430 1.25
4RCP4.6-195-300-2200-A/D 2,200 2 at 150 / 8.8 US gpm at 492.1 ft 4.6 / 20.3 US gpm 195 / 639.8 ft 90-300 90-430 300-430 1.25
4RCP4.6-215-300-2200-A/D 2,200 2 at 160 / 8.8 US gpm at 524.9 ft 4.6 / 20.3 US gpm 215 / 705.4 ft 90-300 90-430 300-430 1.25
4RCP4.6-235-300-2200-A/D 2,200 2 at 170 / 8.8 US gpm at 557.7 ft 4.6 / 20.3 US gpm 235 / 771.0 ft 90-300 90-430 300-430 1.25
4RCP6.5-57-110-750-A/D 750 3 at 45 / 13.2 US gpm at 147.6 ft 6.5 / 28.6 US gpm 57 / 187.0 ft 90-300 90-430 110-430 1.25
4RCP6.5-85-150-1100-A/D 1,100 3 at 65 / 13.2 US gpm at 213.3 ft 6.5 / 28.6 US gpm 85 / 278.9 ft 90-300 90-430 150-430 1.25
4RCP6.5-112-150-1300-A/D 1,300 3 at 90 / 13.2 US gpm at 295.3 ft 6.5 / 28.6 US gpm 112 / 367.5 ft 90-300 90-430 150-430 1.25
4RCP6.5-135-200-1500-A/D 1,500 3 at 105 / 13.2 US gpm at 344.5 ft 6.5 / 28.6 US gpm 135 / 442.9 ft 90-300 90-430 200-430 1.25
4RCP6-175-300-2200-A/D 2,200 3 at 140 / 13.2 US gpm at 459.3 ft 6 / 26.4 US gpm 175 / 574.1 ft 90-300 90-430 300-430 1.25
4RCP6-195-300-2200-A/D 2,200 3 at 150 / 13.2 US gpm at 492.1 ft 6 / 26.4 US gpm 195 / 639.8 ft 90-300 90-430 300-430 1.25
4RCP9-45-110-750-A/D 750 4 at 30 / 17.6 US gpm at 98.4 ft 9 / 39.6 US gpm 45 / 147.6 ft 90-300 90-430 110-430 1.5/2
4RCP9-58-150-1100-A/D 1,100 4 at 46 / 17.6 US gpm at 150.9 ft 9 / 39.6 US gpm 58 / 190.3 ft 90-300 90-430 150-430 1.5/2

4RCP-A/D Technical Data (Part 2)

Models up to 2.2 kW

Model Power (W) Rated duty / m³/h at m Max. flow / m³/h / US gpm Max. head / m / ft AC range (V) DC range (V) PV Vmp (V) Outlet (in)
4RCP9-71-150-1300-A/D 1,300 4 at 55 / 17.6 US gpm at 180.4 ft 9 / 39.6 US gpm 71 / 232.9 ft 90-300 90-430 150-430 1.5/2
4RCP9-85-200-1500-A/D 1,500 4 at 70 / 17.6 US gpm at 229.7 ft 9 / 39.6 US gpm 85 / 278.9 ft 90-300 90-430 200-430 1.5/2
4RCP9.5-125-300-2200-A/D 2,200 4 at 95 / 17.6 US gpm at 311.7 ft 9.5 / 41.8 US gpm 125 / 410.1 ft 90-300 90-430 300-430 1.5/2
4RCP9-155-300-2200-A/D 2,200 4 at 120 / 17.6 US gpm at 393.7 ft 9 / 39.6 US gpm 155 / 508.5 ft 90-300 90-430 300-430 1.5/2
4RCP8.5-185-300-2200-A/D 2,200 4 at 140 / 17.6 US gpm at 459.3 ft 8.5 / 37.4 US gpm 185 / 607.0 ft 90-300 90-430 300-430 1.5/2
4RCP13-36-110-750-A/D 750 6 at 20 / 26.4 US gpm at 65.6 ft 13 / 57.2 US gpm 36 / 118.1 ft 90-300 90-430 150-430 1.5/2
4RCP13-48-150-1100-A/D 1,100 6 at 35 / 26.4 US gpm at 114.8 ft 13 / 57.2 US gpm 49 / 160.8 ft 90-300 90-430 150-430 1.5/2
4RCP13-54-150-1300-A/D 1,300 6 at 37 / 26.4 US gpm at 121.4 ft 13 / 57.2 US gpm 54 / 177.2 ft 90-300 90-430 150-430 1.5/2
4RCP13-60-200-1500-A/D 1,500 6 at 45 / 26.4 US gpm at 147.6 ft 13 / 57.2 US gpm 60 / 196.9 ft 90-300 90-430 200-430 1.5/2
4RCP13-80-200-1500-A/D 1,500 6 at 55 / 26.4 US gpm at 180.4 ft 13 / 57.2 US gpm 80 / 262.5 ft 90-300 90-430 200-430 1.5/2
4RCP13-112-300-2200-A/D 2,200 6 at 70 / 26.4 US gpm at 229.7 ft 13 / 57.2 US gpm 112 / 367.5 ft 90-300 90-430 300-430 1.5/2
4RCP13-135-300-2200-A/D 2,200 6 at 80 / 26.4 US gpm at 262.5 ft 13 / 57.2 US gpm 135 / 442.9 ft 90-300 90-430 300-430 1.5/2
4RCP13-150-300-2200-A/D 2,200 6 at 90 / 26.4 US gpm at 295.3 ft 12 / 52.8 US gpm 150 / 492.1 ft 90-300 90-430 300-430 1.5/2
4RCP15-45-110-750-A/D 750 8 at 25 / 35.2 US gpm at 82.0 ft 15 / 66.0 US gpm 45 / 147.6 ft 90-300 90-430 110-430 2
4RCP15-55-150-1100-A/D 1,100 8 at 35 / 35.2 US gpm at 114.8 ft 15 / 66.0 US gpm 55 / 180.4 ft 90-300 90-430 150-430 2
4RCP16-70-200-1500-A/D 1,500 8 at 50 / 35.2 US gpm at 164.0 ft 16 / 70.4 US gpm 70 / 229.7 ft 90-300 90-430 200-430 2
4RCP16-85-300-2200-A/D 2,200 8 at 65 / 35.2 US gpm at 213.3 ft 16 / 70.4 US gpm 85 / 278.9 ft 90-300 90-430 300-430 2
4RCP15-105-300-2200-A/D 2,200 8 at 75 / 35.2 US gpm at 246.1 ft 15 / 66.0 US gpm 105 / 344.5 ft 90-300 90-430 300-430 2
4RCP17-36-150-1100-A/D 1,100 10 at 25 / 44.0 US gpm at 82.0 ft 17 / 74.8 US gpm 36 / 118.1 ft 90-300 90-430 150-430 2
4RCP17-48-200-1500-A/D 1,500 10 at 30 / 44.0 US gpm at 98.4 ft 17 / 74.8 US gpm 48 / 157.5 ft 90-300 90-430 200-430 2
4RCP17-60-200-1500-A/D 1,500 10 at 35 / 44.0 US gpm at 114.8 ft 17 / 74.8 US gpm 60 / 196.9 ft 90-300 90-430 200-430 2
4RCP17-75-300-2200-A/D 2,200 10 at 50 / 44.0 US gpm at 164.0 ft 17 / 74.8 US gpm 75 / 246.1 ft 90-300 90-430 300-430 2
4RCP17-95-300-2200-A/D 2,200 10 at 60 / 44.0 US gpm at 196.9 ft 17 / 74.8 US gpm 95 / 311.7 ft 90-300 90-430 300-430 2
4RCP21-35-150-1300-A/D 1,300 12 at 25 / 52.8 US gpm at 82.0 ft 21 / 92.5 US gpm 35 / 114.8 ft 90-300 90-430 150-430 2
4RCP21-45-200-1500-A/D 1,500 12 at 30 / 52.8 US gpm at 98.4 ft 21 / 92.5 US gpm 45 / 147.6 ft 90-300 90-430 200-430 2
4RCP20-70-300-2200-A/D 2,200 12 at 55 / 52.8 US gpm at 180.4 ft 22 / 96.9 US gpm 70 / 229.7 ft 90-300 90-430 300-430 2
4RCP30-20-150-1300-A/D 1,300 16 at 14 / 70.4 US gpm at 45.9 ft 30 / 132.1 US gpm 20 / 65.6 ft 90-300 90-430 150-430 2

Model selection — continued

Technical Data (Part 3)

Models up to 2.2 kW

Model Power (W) Rated duty / m³/h at m Max. flow / m³/h / US gpm Max. head / m / ft AC range (V) DC range (V) PV Vmp (V) Outlet (in)
4RCP30-35-200-1500-A/D 1,500 16 at 20 / 70.4 US gpm at 65.6 ft 30 / 132.1 US gpm 35 / 114.8 ft 90-300 90-430 200-430 2
4RCP30-50-300-2200-A/D 2,200 16 at 30 / 70.4 US gpm at 98.4 ft 30 / 132.1 US gpm 50 / 164.0 ft 90-300 90-430 300-430 2

Models above 2.2 kW

Model Power (W) Rated duty / m³/h at m Max. flow / m³/h / US gpm Max. head / m / ft AC range (V) DC range (V) PV Vmp (V) Outlet (in)
4RCP8.5-230-500-3000-A/D 3,000 3 at 204 / 13.2 US gpm at 669.3 ft 8.5 / 37.4 US gpm 230 / 754.6 ft 330-420 200-750 500-750 1.25
4RCP13-171-500-3000-A/D 3,000 6 at 125 / 26.4 US gpm at 410.1 ft 13 / 57.2 US gpm 171 / 561.0 ft 330-420 200-750 500-750 2
4RCP17-159-500-3000-A/D 3,000 8 at 102 / 35.2 US gpm at 334.6 ft 17 / 74.8 US gpm 159 / 521.7 ft 330-420 200-750 500-750 2
4RCP18.7-118-500-3000-A/D 3,000 10 at 80 / 44.0 US gpm at 262.5 ft 18.7 / 82.3 US gpm 118 / 387.1 ft 330-420 200-750 500-750 2
4RCP25-83-500-3000-A/D 3,000 12 at 56 / 52.8 US gpm at 183.7 ft 25 / 110.1 US gpm 83 / 272.3 ft 330-420 200-750 500-750 2
4RCP33-66-500-3000-A/D 3,000 16 at 42 / 70.4 US gpm at 137.8 ft 33 / 145.3 US gpm 66 / 216.5 ft 330-420 200-750 500-750 2
4RCP41-52-500-3000-A/D 3,000 20 at 38 / 88.1 US gpm at 124.7 ft 41 / 180.5 US gpm 52 / 170.6 ft 330-420 200-750 500-750 3
4RCP8.6-303-500-4000-A/D 4,000 3 at 268 / 13.2 US gpm at 879.3 ft 8.6 / 37.9 US gpm 303 / 994.1 ft 330-420 200-750 500-750 1.25
4RCP13-220-500-4000-A/D 4,000 6 at 163 / 26.4 US gpm at 534.8 ft 13 / 57.2 US gpm 220 / 721.8 ft 330-420 200-750 500-750 2
4RCP17.5-196-500-4000-A/D 4,000 8 at 138 / 35.2 US gpm at 452.8 ft 17.5 / 77.1 US gpm 196 / 643.0 ft 330-420 200-750 500-750 2
4RCP19-142-500-4000-A/D 4,000 10 at 103 / 44.0 US gpm at 337.9 ft 19 / 83.7 US gpm 142 / 465.9 ft 330-420 200-750 500-750 2
4RCP25-107-500-4000-A/D 4,000 12 at 77 / 52.8 US gpm at 252.6 ft 25 / 110.1 US gpm 107 / 351.0 ft 330-420 200-750 500-750 2
4RCP33-76-500-4000-A/D 4,000 16 at 57 / 70.4 US gpm at 187.0 ft 33 / 145.3 US gpm 76 / 249.3 ft 330-420 200-750 500-750 2
4RCP41-60-500-4000-A/D 4,000 20 at 43 / 88.1 US gpm at 141.1 ft 41 / 180.5 US gpm 60 / 196.9 ft 330-420 200-750 500-750 3

Maximum flow and maximum head are not simultaneous. Confirm the required point on the selected model curve. Outlet dimensions do not identify BSP or NPT threads; specify the required connection standard.

PV array sizing

The catalogue recommends PV rated power of at least 1.3 times pump power as initial guidance. Final array design must account for site conditions, module voltage and current, cable losses and the matched inverter. Operating DC voltage and PV Vmp are not the array open-circuit voltage (Voc) limit. Check cold-weather string Voc against the actual inverter maximum before connection.

Installation and controls

  • Use the selected inverter manual for AC/PV terminals, grounding, motor connections and protective devices.
  • Keep the submersible pump underwater during operation and use suitable suspension equipment; never lift it by its electrical cable.
  • Confirm water-level sensors, pressure-control accessories and remote-control options in the system specification.
  • Use qualified personnel to commission the system. Confirm the permitted supply arrangement before enabling any simultaneous AC/PV mode.

Applications

  • Agricultural irrigation: match the operating point to field pipework and irrigation demand.
  • Livestock and farm supply: fill storage tanks from a suitable well.
  • Rural water transfer: combine daytime solar pumping with an appropriately specified AC supply option.
  • Scheduled water delivery: size pump capacity and storage for the daily requirement and available power.

Confirm water quality, allowable solids, bore clearance and installation depth for the selected model.

Request Your 4RCP-A/D System Selection

Send your country, bore diameter, pumping water level, delivery height, pipe length, required flow or daily volume, and quantity. Include the AC supply voltage/phase and PV module Vmp, Voc and wattage. We will help specify a pump, inverter and supply arrangement for your site.

Related Products

Related News

You dream of a pool powered by free sunlight, but the mystery of installation costs holds you back. You worry […]

Scroll to Top

Talk to RAFSUN About Your Pump Requirements

Rafsun Solar Water Pump-0

Get A Free Quote Now !

VSD Contact Form

See our Privacy Policy for how we handle your information.

Contact Rafsun to get the service for free

RAFSUN BWD, HMS, RUC and REB variable-speed booster pump range

Get A Free Quote Now !

VSD Contact Form

See our Privacy Policy for how we handle your information.