3 Inch Solar Well Pump with Stainless Steel Impeller
3RCS DC solar submersible pumps with stainless steel impellers for well-to-tank water transfer, livestock watering and irrigation. Compare models by flow at your required total dynamic head.
- 3-inch pump families; verify actual bore clearance and pump dimensions.
- Stainless steel impellers and permanent-magnet brushless DC motor.
- Matched solar controller with MPPT and operating display.
- Selected models below: 300-1,500 W.
- Model-dependent limits up to 6 m³/h (26.4 US gpm) or 135 m (442.9 ft); these limits do not occur together.
3RCS Solar Well Pump Overview
The RAFSUN 3RCS range uses stainless steel impellers to lift water from a suitable well into storage or a distribution system. The permanent-magnet brushless DC motor operates with its matched controller, which tracks available photovoltaic power.
Match the pump to the real duty
Start with your required flow at total dynamic head. Total head includes the pumping water level, elevation to the delivery point, required outlet pressure and pipe friction losses. Well depth alone is not enough to select a model. Ask for the curve of the selected model and check the operating point before ordering.
Plan the daily water supply
Solar pumping output changes with irradiance and array configuration. Size the system around daily water demand and local solar conditions; a storage tank can hold water pumped during the day. For projects needing an AC supply option, compare the hybrid solar submersible range.
Compare other diameters and pumping mechanisms in our DC solar well pump range.
3RCS Solar Pump Technical Data
Selected catalogue models. Confirm the exact model, controller and electrical configuration with your quotation. US gpm and feet are rounded conversions of the metric catalogue data.
3RCS Model Selection
| Model | Rated voltage (V) | Power (W) | Max. flow / m³/h / US gpm | Max. head / m / ft | Outlet (in) | PV Vmp (V) | Array Voc (V) |
|---|---|---|---|---|---|---|---|
| 3RCS4-35-24-300 | 24 | 300 | 4 / 17.6 US gpm | 35 / 114.8 ft | 1.25 | 24-48 | Below 55 |
| 3RCS4-50-48-400 | 48 | 400 | 4 / 17.6 US gpm | 50 / 164.0 ft | 1.25 | 48-96 | Below 105 |
| 3RCS4.5-80-48-600 | 48 | 600 | 4.5 / 19.8 US gpm | 80 / 262.5 ft | 1.25 | 48-96 | Below 105 |
| 3RCS4.5-80-72-600 | 72 | 600 | 4.5 / 19.8 US gpm | 80 / 262.5 ft | 1.25 | 72-144 | Below 160 |
| 3RCS4.5-95-72-750 | 72 | 750 | 4.5 / 19.8 US gpm | 95 / 311.7 ft | 1.25 | 72-144 | Below 160 |
| 3RCS4.5-112-72-1100 | 72 | 1100 | 4.5 / 19.8 US gpm | 112 / 367.5 ft | 1.25 | 72-144 | Below 160 |
| 3RCS4.5-112-96-1100 | 96 | 1100 | 4.5 / 19.8 US gpm | 112 / 367.5 ft | 1.25 | 96-192 | Below 210 |
| 3RCS4.5-120-96-1300 | 96 | 1300 | 4.5 / 19.8 US gpm | 120 / 393.7 ft | 1.25 | 96-192 | Below 210 |
| 3RCS4.5-120-110-1300 | 110 | 1300 | 4.5 / 19.8 US gpm | 120 / 393.7 ft | 1.25 | 110-192 | Below 210 |
| 3RCS4.5-135-110-1500 | 110 | 1500 | 4.5 / 19.8 US gpm | 135 / 442.9 ft | 1.25 | 110-192 | Below 210 |
| 3RCS6-44-48-600 | 48 | 600 | 6 / 26.4 US gpm | 44 / 144.4 ft | 1.25 | 48-96 | Below 105 |
| 3RCS6-44-72-600 | 72 | 600 | 6 / 26.4 US gpm | 44 / 144.4 ft | 1.25 | 72-144 | Below 160 |
| 3RCS6-60-72-750 | 72 | 750 | 6 / 26.4 US gpm | 60 / 196.9 ft | 1.25 | 72-144 | Below 160 |
| 3RCS6-80-96-1100 | 96 | 1100 | 6 / 26.4 US gpm | 80 / 262.5 ft | 1.25 | 96-192 | Below 210 |
| 3RCS6-80-110-1100 | 110 | 1100 | 6 / 26.4 US gpm | 80 / 262.5 ft | 1.25 | 110-192 | Below 210 |
| 3RCS6-95-110-1500 | 110 | 1500 | 6 / 26.4 US gpm | 95 / 311.7 ft | 1.25 | 110-192 | Below 210 |
Maximum flow and maximum head are separate limits, not a simultaneous operating point. Use the model performance curve to confirm flow at the required total head. Outlet size alone does not specify BSP or NPT threads; confirm the required connection standard.
PV array and controller matching
The catalogue recommends PV rated power of at least 1.3 times pump power. This is initial sizing guidance; final design depends on site solar conditions, module data, controller limits and cable losses. The Vmp and Voc columns are different: array open-circuit voltage must remain below the listed limit, including cold-weather conditions. Confirm the supplied controller nameplate before connecting the array.
Installation and operation
- Keep the submersible pump underwater during operation; do not test it dry.
- Use a suitable rope or suspension cable to lower and lift the pump; do not lift by the power cable.
- Use correctly sized extension cables and follow the controller wiring diagram.
- The DC controller manual describes well-water and tank-level inputs. Confirm the required sensors and wiring with your system specification.
- Match water quality, installation depth and site conditions to the approved pump specification before commissioning.
Request Your 3RCS Pump Selection
Send your country, bore diameter, pumping water level, delivery height, pipe length, required flow or daily water volume, and order quantity. Include existing PV module Vmp/Voc and wattage if available. We will help match the pump and controller before preparing a quotation.
3RCS Solar Pump Applications
- Farm and livestock supply: transfer well water into storage tanks or trough systems.
- Rural water transfer: supply a tank where grid access is limited.
- Irrigation: select a model that meets the flow and pressure required by the irrigation layout.
Confirm water quality and allowable solids before selecting the pump. Drinking-water use depends on the water source, materials documentation and complete installation; this page does not make a drinking-water certification claim.