Skip image slider
4-6 Inch Solar Well Pump With Stainless Steel Impeller
4-6 Inch Solar Well Pump With Stainless Steel Impeller

4/6 Inch Solar Well Pump With Stainless Steel Impeller

4RCS/6RCS DC solar submersible pumps with stainless steel impellers for well-to-tank water transfer, livestock watering and irrigation. Compare models by flow at your required total dynamic head.

  • 4-inch and 6-inch pump families; verify actual bore clearance and pump dimensions.
  • Stainless steel impellers and permanent-magnet brushless DC motor.
  • Matched solar controller with MPPT and operating display.
  • Selected models below: 500-1,500 W.
  • Model-dependent limits up to 42 m³/h (184.9 US gpm) or 203 m (666.0 ft); these limits do not occur together.
Products Categories
Get A Free Quote
Contact Form

4RCS/6RCS Solar Well Pump Overview

The RAFSUN 4RCS/6RCS range uses stainless steel impellers to lift water from a suitable well into storage or a distribution system. The permanent-magnet brushless DC motor operates with its matched controller, which tracks available photovoltaic power.

40Catalogue models
500–1,500 WPump power range
MPPTMatched DC controller

Match the pump to the real duty

Start with your required flow at total dynamic head. Total head includes the pumping water level, elevation to the delivery point, required outlet pressure and pipe friction losses. Well depth alone is not enough to select a model. Ask for the curve of the selected model and check the operating point before ordering.

Choose the pump diameter and hydraulic range

4RCS includes lower-flow, higher-head models as well as models for larger transfer duties. 6RCS provides higher-flow, lower-head options. A 6-inch pump needs a suitable bore or installation space; it is not a direct fit for a 4-inch well.

Plan the daily water supply

Solar pumping output changes with irradiance and array configuration. Size the system around daily water demand and local solar conditions; a storage tank can hold water pumped during the day. For projects needing an AC supply option, compare the hybrid solar submersible range.

Compare other diameters and pumping mechanisms in our DC solar well pump range.

Technical Data (Part 1)

Selected catalogue models. Confirm the exact model, controller and electrical configuration with your quotation. US gpm and feet are rounded conversions of the metric catalogue data.

4RCS Model Selection

Model Rated voltage (V) Power (W) Max. flow / m³/h / US gpm Max. head / m / ft Outlet (in) PV Vmp (V) Array Voc (V)
4RCS4-50-48-550 48 550 4 / 17.6 US gpm 50 / 164.0 ft 1.25 48-96 Below 105
4RCS4-80-48-750 48 750 4 / 17.6 US gpm 80 / 262.5 ft 1.25 48-96 Below 105
4RCS4-80-72-750 72 750 4 / 17.6 US gpm 80 / 262.5 ft 1.25 72-144 Below 160
4RCS4-96-72-1100 72 1100 4 / 17.6 US gpm 96 / 315.0 ft 1.25 72-144 Below 160
4RCS4-140-96-1300 96 1300 4 / 17.6 US gpm 140 / 459.3 ft 1.25 96-192 Below 210
4RCS4-154-110-1400 110 1400 4 / 17.6 US gpm 154 / 505.2 ft 1.25 110-192 Below 210
4RCS4.5-203-110-1500 110 1500 4.5 / 19.8 US gpm 203 / 666.0 ft 1.25 110-192 Below 210
4RCS7.5-35-48-550 48 550 7.5 / 33.0 US gpm 35 / 114.8 ft 1.25 48-96 Below 105
4RCS7.5-45-48-750 48 750 7.5 / 33.0 US gpm 45 / 147.6 ft 1.25 48-96 Below 105
4RCS7.5-60-72-1100 72 1100 7.5 / 33.0 US gpm 60 / 196.9 ft 1.25 72-144 Below 160
4RCS7.5-80-96-1300 96 1300 7.5 / 33.0 US gpm 80 / 262.5 ft 1.25 96-192 Below 210
4RCS7.5-95-96-1300 96 1300 7.5 / 33.0 US gpm 95 / 311.7 ft 1.25 96-192 Below 210
4RCS7.5-105-110-1400 110 1400 7.5 / 33.0 US gpm 105 / 344.5 ft 1.25 110-192 Below 210
4RCS7.5-115-110-1500 110 1500 7.5 / 33.0 US gpm 115 / 377.3 ft 1.25 110-192 Below 210
4RCS5.2-36-48-500 48 500 5.2 / 22.9 US gpm 36 / 118.1 ft 1.25 48-96 Below 105
4RCS5.2-45-48-550 48 550 5.2 / 22.9 US gpm 45 / 147.6 ft 1.25 48-96 Below 105
4RCS5.2-54-48-650 48 650 5.2 / 22.9 US gpm 54 / 177.2 ft 1.25 48-96 Below 105
4RCS5.2-54-72-650 72 650 5.2 / 22.9 US gpm 54 / 177.2 ft 1.25 72-144 Below 160
4RCS5.2-67-48-750 48 750 5.2 / 22.9 US gpm 67 / 219.8 ft 1.25 48-96 Below 105
4RCS5.2-67-72-750 72 750 5.2 / 22.9 US gpm 67 / 219.8 ft 1.25 72-144 Below 160

4RCS/6RCS Solar Pump Technical Data

4RCS Model Selection

Model Rated voltage (V) Power (W) Max. flow / m³/h / US gpm Max. head / m / ft Outlet (in) PV Vmp (V) Array Voc (V)
4RCS5.2-80-72-900 72 900 5.2 / 22.9 US gpm 80 / 262.5 ft 1.25 72-144 Below 160
4RCS5.2-101-72-1100 72 1100 5.2 / 22.9 US gpm 101 / 331.4 ft 1.25 72-144 Below 160
4RCS5.2-101-96-1100 96 1100 5.2 / 22.9 US gpm 101 / 331.4 ft 1.25 96-192 Below 210
4RCS5.2-120-96-1300 96 1300 5.2 / 22.9 US gpm 120 / 393.7 ft 1.25 96-192 Below 210
4RCS5.2-132-110-1400 110 1400 5.2 / 22.9 US gpm 132 / 433.1 ft 1.25 110-192 Below 210
4RCS5.2-146-110-1500 110 1500 5.2 / 22.9 US gpm 146 / 479.0 ft 1.25 110-192 Below 210
4RCS19-23-72-1100 72 1100 19 / 83.7 US gpm 23 / 75.5 ft 2 72-144 Below 160
4RCS19-35-96-1300 96 1300 19 / 83.7 US gpm 35 / 114.8 ft 2 96-192 Below 210
4RCS20-46-110-1500 110 1500 19 / 83.7 US gpm 46 / 150.9 ft 2 110-192 Below 210
4RCS25-26-110-1500 110 1500 25 / 110.1 US gpm 26 / 85.3 ft 2 110-192 Below 210
4RCS17-60-110-1500 110 1500 17 / 74.8 US gpm 60 / 196.9 ft 2 110-192 Below 210
4RCS10-21-48-550 48 550 10 / 44.0 US gpm 21 / 68.9 ft 2 48-96 Below 105
4RCS10-32-48-750 48 750 10 / 44.0 US gpm 32 / 105.0 ft 2 48-96 Below 105
4RCS10-32-72-750 72 750 10 / 44.0 US gpm 32 / 105.0 ft 2 72-144 Below 160
4RCS10-45-72-1100 72 1100 10 / 44.0 US gpm 43 / 141.1 ft 2 72-144 Below 160
4RCS10-60-96-1300 96 1300 10 / 44.0 US gpm 60 / 196.9 ft 2 96-192 Below 210
4RCS10-72-110-1500 110 1500 10 / 44.0 US gpm 72 / 236.2 ft 2 110-192 Below 210

6RCS Model Selection

Model Rated voltage (V) Power (W) Max. flow / m³/h / US gpm Max. head / m / ft Outlet (in) PV Vmp (V) Array Voc (V)
6RCS30-19-72-1100 72 1100 30 / 132.1 US gpm 19 / 62.3 ft 3 72-144 Below 160
6RCS36-22-96-1500 96 1500 36 / 158.5 US gpm 22 / 72.2 ft 3 96-192 Below 210
6RCS42-20-110-1500 110 1500 42 / 184.9 US gpm 20 / 65.6 ft 3 110-192 Below 210

Maximum flow and maximum head are separate limits, not a simultaneous operating point. Use the model performance curve to confirm flow at the required total head. Outlet size alone does not specify BSP or NPT threads; confirm the required connection standard.

PV array and controller matching

The catalogue recommends PV rated power of at least 1.3 times pump power. This is initial sizing guidance; final design depends on site solar conditions, module data, controller limits and cable losses. The Vmp and Voc columns are different: array open-circuit voltage must remain below the listed limit, including cold-weather conditions. Confirm the supplied controller nameplate before connecting the array.

Installation and operation

  • Keep the submersible pump underwater during operation; do not test it dry.
  • Use a suitable rope or suspension cable to lower and lift the pump; do not lift by the power cable.
  • Use correctly sized extension cables and follow the controller wiring diagram.
  • The DC controller manual describes well-water and tank-level inputs. Confirm the required sensors and wiring with your system specification.
  • Match water quality, installation depth and site conditions to the approved pump specification before commissioning.

Request Your 4RCS/6RCS Pump Selection

Send your country, bore diameter, pumping water level, delivery height, pipe length, required flow or daily water volume, and order quantity. Include existing PV module Vmp/Voc and wattage if available. We will help match the pump and controller before preparing a quotation.

4RCS/6RCS Solar Pump Applications

  • Farm and livestock supply: transfer well water into storage tanks or trough systems.
  • Rural water transfer: supply a tank where grid access is limited.
  • Irrigation: select a model that meets the flow and pressure required by the irrigation layout.

Confirm water quality and allowable solids before selecting the pump. Drinking-water use depends on the water source, materials documentation and complete installation; this page does not make a drinking-water certification claim.

Related Products

Related News

Scroll to Top

Talk to RAFSUN About Your Pump Requirements

Rafsun Solar Water Pump-0

Get A Free Quote Now !

VSD Contact Form

Contact Rafsun to get the service for free

RAFSUN flagship inverter booster pumps product lineup for factory direct sales, featuring BWD Cullinan (900–2200W), BWE Bentayga (750–1500W), RUC Urus (370–1100W), and REB Huracan (370–750W). These high-efficiency RAFSUN Inverter Booster Pumps deliver constant water pressure, energy savings, and reliable performance for residential, commercial, and multi-story building applications.

Get A Free Quote Now !

VSD Contact Form