6 Inch AC/DC Solar Submersible Pump With Stainless Steel Impeller
6RCS-A/D 6-inch hybrid solar submersible pumps with stainless steel impellers. Match PV operation and an approved AC supply option to your well, water demand and installation.
- Stainless steel impellers in a 6-inch submersible pump family.
- Permanent-magnet motor with a matched hybrid solar inverter.
- PV and AC supply options for a correctly configured system.
- Selected catalogue models: 1,100-4,000 W.
- Model-dependent limits up to 65 m³/h (286.2 US gpm) or 101 m (331.4 ft); maximum flow and maximum head are separate limits.
6RCS-A/D Hybrid Solar Submersible Pump Overview
The RAFSUN 6RCS-A/D combines a submersible pump with stainless steel impellers and a compatible hybrid solar inverter. PV power supports daytime pumping, while a correctly matched grid or generator supply can support water delivery when solar power is insufficient.
Select by the required operating point
Choose a model for flow at total dynamic head, including the pumping water level, delivery elevation, required pressure and pipe losses. The rated flow and rated head below form the catalogue duty point; maximum flow and maximum head must not be used together as a duty point.
Match both electrical supplies
The AC input, DC input and PV Vmp columns describe different quantities. Choose the pump and inverter as a matched system, and confirm supply phase, frequency, voltage and PV string design with the quotation. AC/PV operating behaviour and any simultaneous-input mode depend on the supplied inverter configuration.
Build around the water demand
Use daily water volume, local sunshine and available storage to plan solar operation. Specify the AC backup requirement for periods when solar energy is unavailable. Compare related sizes in the hybrid solar submersible range, or review DC solar well pumps for a DC system.
6RCS-A/D Model and Electrical Comparison
Selected catalogue models. Rated duty is shown as flow at head. US gpm and feet are rounded conversions. Electrical figures below are the model catalogue ranges; confirm the supplied inverter nameplate and wiring instructions before installation.
Models up to 2.2 kW
| Model | Power (W) | Rated duty / m³/h at m | Max. flow / m³/h / US gpm | Max. head / m / ft | AC range (V) | DC range (V) | PV Vmp (V) | Outlet (in) |
|---|---|---|---|---|---|---|---|---|
| 6RCS33-19-150-1100-A/D | 1,100 | 17 at 13 / 74.8 US gpm at 42.7 ft | 33 / 145.3 US gpm | 19 / 62.3 ft | 90-300 | 90-430 | 150-430 | 3 |
| 6RCS37-22-200-1500-A/D | 1,500 | 17 at 16 / 74.8 US gpm at 52.5 ft | 37 / 162.9 US gpm | 22 / 72.2 ft | 90-300 | 90-430 | 200-430 | 3 |
| 6RCS37-40-300-2200-A/D | 2,200 | 17 at 25 / 74.8 US gpm at 82.0 ft | 37 / 162.9 US gpm | 40 / 131.2 ft | 90-300 | 90-430 | 300-430 | 3 |
| 6RCS30-55-300-2200-A/D | 2,200 | 17 at 29 / 74.8 US gpm at 95.1 ft | 33 / 145.3 US gpm | 55 / 180.4 ft | 90-300 | 90-430 | 300-430 | 3 |
| 6RCS40-17-200-1500-A/D | 1,500 | 20 at 16 / 88.1 US gpm at 52.5 ft | 40 / 176.1 US gpm | 24 / 78.7 ft | 90-300 | 90-430 | 200-430 | 3 |
| 6RCS37-43-300-2200-A/D | 2,200 | 20 at 23 / 88.1 US gpm at 75.5 ft | 37 / 162.9 US gpm | 43 / 141.1 ft | 90-300 | 90-430 | 300-430 | 3 |
| 6RCS35-50-300-2200-A/D | 2,200 | 20 at 27 / 88.1 US gpm at 88.6 ft | 35 / 154.1 US gpm | 50 / 164.0 ft | 90-300 | 90-430 | 300-430 | 3 |
Models above 2.2 kW
| Model | Power (W) | Rated duty / m³/h at m | Max. flow / m³/h / US gpm | Max. head / m / ft | AC range (V) | DC range (V) | PV Vmp (V) | Outlet (in) |
|---|---|---|---|---|---|---|---|---|
| 6RCS30-72-500-3000-A/D | 3,000 | 14 at 43 / 61.6 US gpm at 141.1 ft | 30 / 132.1 US gpm | 72 / 236.2 ft | 330-420 | 200-750 | 500-750 | 3 |
| 6RCS37-63-500-3000-A/D | 3,000 | 17 at 42 / 74.8 US gpm at 137.8 ft | 37 / 162.9 US gpm | 63 / 206.7 ft | 330-420 | 200-750 | 500-750 | 3 |
| 6RCS46-51-500-3000-A/D | 3,000 | 20 at 35 / 88.1 US gpm at 114.8 ft | 46 / 202.5 US gpm | 51 / 167.3 ft | 330-420 | 200-750 | 500-750 | 3 |
| 6RCS65-24-500-3000-A/D | 3,000 | 30 at 19 / 132.1 US gpm at 62.3 ft | 65 / 286.2 US gpm | 24 / 78.7 ft | 330-420 | 200-750 | 500-750 | 3 |
| 6RCS30-101-500-4000-A/D | 4,000 | 14 at 61 / 61.6 US gpm at 200.1 ft | 30 / 132.1 US gpm | 101 / 331.4 ft | 330-420 | 200-750 | 500-750 | 3 |
| 6RCS46-68-500-4000-A/D | 4,000 | 20 at 49 / 88.1 US gpm at 160.8 ft | 46 / 202.5 US gpm | 68 / 223.1 ft | 330-420 | 200-750 | 500-750 | 3 |
| 6RCS65-47-500-4000-A/D | 4,000 | 30 at 36 / 132.1 US gpm at 118.1 ft | 65 / 286.2 US gpm | 47 / 154.2 ft | 330-420 | 200-750 | 500-750 | 3 |
Maximum flow and maximum head are not simultaneous. Confirm the required point on the selected model curve. Outlet dimensions do not identify BSP or NPT threads; specify the required connection standard.
PV array sizing
The catalogue recommends PV rated power of at least 1.3 times pump power as initial guidance. Final array design must account for site conditions, module voltage and current, cable losses and the matched inverter. Operating DC voltage and PV Vmp are not the array open-circuit voltage (Voc) limit. Check cold-weather string Voc against the actual inverter maximum before connection.
Installation and controls
- Use the selected inverter manual for AC/PV terminals, grounding, motor connections and protective devices.
- Keep the submersible pump underwater during operation and use suitable suspension equipment; never lift it by its electrical cable.
- Confirm water-level sensors, pressure-control accessories and remote-control options in the system specification.
- Use qualified personnel to commission the system. Confirm the permitted supply arrangement before enabling any simultaneous AC/PV mode.
Confirm the duty point against the supplied performance curve before ordering.
6RCS-A/D Hybrid Solar Pump Applications
- Agricultural irrigation: match the operating point to field pipework and irrigation demand.
- Livestock and farm supply: fill storage tanks from a suitable well.
- Rural water transfer: combine daytime solar pumping with an appropriately specified AC supply option.
- Scheduled water delivery: size pump capacity and storage for the daily requirement and available power.
Confirm water quality, allowable solids, bore clearance and installation depth for the selected model.
Request Your 6RCS-A/D System Selection
Send your country, bore diameter, pumping water level, delivery height, pipe length, required flow or daily volume, and quantity. Include the AC supply voltage/phase and PV module Vmp, Voc and wattage. We will help specify a pump, inverter and supply arrangement for your site.